A held batch or individual access
Describe which goods must be reached during the day. Marine T-floor loading needs its own airflow plan; an open aisle drawn for another floor does not establish a suitable loading pattern.
Ask for written quotes. Compare the price and the work included for your project.


Compare standard and high-cube refrigerated storage on the same 40ft footprint. Select the height, then match the load, refrigeration equipment and delivery route.
Request a delivered quote
The supplier confirms the actual unit, working condition and delivery details.
Request a delivered quote
The supplier confirms the actual unit, working condition and delivery details.
These paired examples share an 11.602 × 2.276 m interior floor. High cube adds 305 mm of published inside height, about 12in, while keeping the same floor length and width.
Swipe the table to see every column.
| Measurement | Length | Width | Height |
|---|---|---|---|
| Exterior, imperial units | 40 ft | 8 ft | 8 ft 6 in |
| Exterior, metric | 12.192 m | 2.438 m | 2.591 m |
| Interior, metric | 11.602 m | 2.276 m | 2.226 m |
| Cargo-door opening | — | 2.276 m | 2.299 m |
Exterior, interior and cargo-door figures describe this one documented example. Door opening and interior height are separate measurements; confirm the actual unit, floor and load line.
Swipe the table to see every column.
| Measurement | Length | Width | Height |
|---|---|---|---|
| Exterior, imperial units | 40 ft | 8 ft | 9 ft 6 in |
| Exterior, metric | 12.192 m | 2.438 m | 2.896 m |
| Interior, metric | 11.602 m | 2.276 m | 2.531 m |
| Cargo-door opening | — | 2.276 m | 2.603 m |
Exterior, interior and cargo-door figures describe this one documented example. Door opening and interior height are separate measurements; confirm the actual unit, floor and load line.
Describe which goods must be reached during the day. Marine T-floor loading needs its own airflow plan; an open aisle drawn for another floor does not establish a suitable loading pattern.
Specify the target temperature, outdoor conditions, batch size and door routine. Cooling warm arrivals or freezing a batch needs a separate duty assessment from holding already-cold stock.
Standard and high-cube examples have separate published equipment specifications. Confirm the actual machine, its nameplate and the site connection before delivery.
Swipe the table to see every column.
| Documented dimension example | Published temperature range | Published supply |
|---|---|---|
| 40ft standard height | −20 to 70°F (−28.9 to 21.1°C) | Typical machinery: 208/230 or 380/460 V, three phase, 50/60 Hz; confirm the actual combination and current |
| 40ft high cube | −10 to 70°F (−23.3 to 21.1°C) | 230 V / 60 A or 460 V / 30 A, three phase; confirm frequency and connection |
These model-specific specifications do not guarantee an offered unit’s performance or daily electricity use. A converted single-phase freezer is a separate configuration. Use a representative operating test and metered kWh for the intended holding conditions.
Choose standard height when the packaged load fits its headroom; compare high cube for taller goods on the same floor, then verify door clearance, the load line and the long delivery approach.
The paired interiors are 2.226 m high for standard and 2.531 m for high cube. Their door openings are 2.299 m and 2.603 m high respectively. Doorway and interior heights are different limits.
Both dimension examples have an 11.602 × 2.276 m interior floor. Extra height leaves that floor unchanged; an arrangement that fits geometrically still needs the correct loading and airflow instructions.
The standard reference lists typical three-phase machinery options rather than one unit’s nameplate. The high-cube reference lists its own supply ratings. A voltage transformer with three-phase input does not establish single-phase compatibility.
Keep standard/high-cube selection attached to the delivered unit, its cooling equipment and its placement plan. The delivery operator and offered machinery determine the access requirements.
Compare equipment scope by height, condition and refrigeration system. Request a current Canadian quote in CAD for the exact configuration, testing, delivery and site electrical work.
Swipe the table to see every column.
| Configuration and inclusions | Advertised price |
|---|---|
| 40ft used refrigerated container with working refrigeration; power connection and commissioning excluded | CA$9,850–CA$11,950 · tax not stated · checked 16 Oct 2026 |
Your supplier confirms availability and the final quote for the assigned unit. Confirm delivery, unloading, taxes, any transformer or conversion and site electrical work separately.
Request the machine identity, a dated operating test at the required temperature and checks of alarms, defrost and door seals.
Compare insulation, floor, repairs and equipment age separately. A new motor can be fitted to a used box; request the warranty terms for each.
Have the quote separate equipment, any transformer or conversion, transport, unloading, taxes and site electrical work.
The installed 40ft rectangle is only part of the site plan. Confirm the delivery truck’s straight approach, turns, tilt clearance and unloading method, then set the doors and machinery-end access before placement.
The paired 40ft examples have the same 11.602 × 2.276 m interior floor. High cube adds 305 mm of published interior height. Check load height, doorway clearance and the actual unit’s load line.
One high-cube room adds height, without separate temperature zones. Give each product’s required conditions in the request; different temperatures may need separate equipment or a specifically designed arrangement.
The marine dimension examples here use three phase. A separate used-box/new-freezer-motor offer lists 208–240 V single phase on dedicated 40 A service. Confirm the selected machine and connection; it is not an ordinary 120 V outlet.
Specify standard or high cube, working condition, cooling duty, site supply, delivery postal code and unloading access. Ask for equipment, options, a dated refrigeration test, delivery, unloading, taxes and electrical setup as separate items.
Compare the cooling needs and delivery work together.