THE SPACE YOU CAN PLAN AROUND

Exterior, interior and door dimensions

These paired examples share an 11.602 × 2.276 m interior floor. High cube adds 305 mm of published inside height, while keeping the same floor length and width.

40ft standard-height cargo-door example

Swipe the table to see every column.

MeasurementLengthWidthHeight
Exterior, metric12.192 m2.438 m2.591 m
Interior, metric11.602 m2.276 m2.226 m
Cargo-door opening—2.276 m2.299 m

These dimensions are examples for particular models. Check the offered unit’s measurements, openings, ratings and usable clearances before planning storage, transport or installation.

Exterior, interior and cargo-door figures describe this one documented example. Door opening and interior height are separate measurements; confirm the actual unit, floor and load line.

40ft high-cube cargo-door example

Swipe the table to see every column.

MeasurementLengthWidthHeight
Exterior, metric12.192 m2.438 m2.896 m
Interior, metric11.602 m2.276 m2.531 m
Cargo-door opening—2.276 m2.603 m

These dimensions are examples for particular models. Check the offered unit’s measurements, openings, ratings and usable clearances before planning storage, transport or installation.

MATCH THE LOAD AND THE MACHINE

Plan the long room around airflow, retrieval and power

A held batch or individual access

Describe which goods must be reached during the day. Marine T-floor loading needs its own airflow plan; an open aisle drawn for another floor does not establish a suitable loading pattern.

Temperature and incoming load

Specify the target temperature, outdoor conditions, batch size and door routine. Cooling warm arrivals or freezing a batch needs a separate duty assessment from holding already-cold stock.

Assigned refrigeration machine

Standard and high-cube examples have separate published equipment specifications. Confirm the actual machine, its nameplate and the site connection before delivery.

Swipe the table to see every column.

Operating requirementWhat the supplier must confirmSite confirmation
Holding temperatureRequired setpoint, product temperature and dated test for the actual machineAirflow, loading, insulation and door-opening routine
Cooling dutyWhether the unit can perform the required holding or pull-down dutyIncoming batch size and temperature; local ambient conditions
Electrical supplyNameplate voltage, phase, 50 Hz compatibility, current and connectorLicensed electrician checks circuit, protection, earthing and any transformer

Confirm the assigned unit’s nameplate voltage, phase, frequency, current and connector. Australian supply is nominally 230 V single phase or 400 V three phase at 50 Hz; a licensed electrician must confirm equipment compatibility, circuit protection and any transformer.

INSIDE THE UNIT. AT YOUR SITE.

Technical checks for standard or high-cube 40ft storage

Choose standard height when the packaged load fits its headroom; compare high cube for taller goods on the same floor, then verify door clearance, the load line and the long delivery approach.

Check loaded height at the opening and inside

The paired interiors are 2.226 m high for standard and 2.531 m for high cube. Their door openings are 2.299 m and 2.603 m high respectively. Doorway and interior heights are different limits.

  • Provide the full packaged height, including pallet and any wrapping.
  • Check the actual doorway, interior and marked load line for the chosen height.
  • Confirm the offered unit’s load and handling limits before planning stacking.

Plan retrieval along the 11.602 m floor

Both dimension examples have an 11.602 × 2.276 m interior floor. Extra height leaves that floor unchanged; an arrangement that fits geometrically still needs the correct loading and airflow instructions.

  • Show how the farthest goods will be reached and removed during the storage cycle.
  • Confirm the floor’s cargo boundary and the offered unit’s loading instructions.
  • Use a separate access plan if the intended work is frequent picking rather than a held batch.

Resolve the assigned machine and any transformer

The standard reference lists typical three-phase machinery options rather than one unit’s nameplate. The high-cube reference lists its own supply ratings. A voltage transformer with three-phase input does not establish single-phase compatibility.

  • Request the machine identity and exact nameplate voltage, phase, frequency and current.
  • Have the supplier specify any transformer, its input requirements and the connection scope.
  • Obtain a dated run record for the selected machine at the required temperature, with test conditions and alarm or defrost checks.

Receive the selected height and service access

Keep standard/high-cube selection attached to the delivered unit, its cooling equipment and its placement plan. The delivery operator and offered machinery determine the access requirements.

  • Match the height configuration and unit/machine identifiers to the quote and condition photographs.
  • Record the cargo-door seals, floor, insulation and listed repairs at handover.
  • Confirm the agreed door orientation and refrigeration-end ventilation and maintenance access.
  • Keep the dated refrigeration test, itemised equipment scope, warranty terms and service contact with the acceptance records.
EQUIPMENT. CONDITION. DELIVERED TOTAL.

Compare Australian reefer quotes by actual equipment and scope

Compare Australian proposals for the same temperature duty, condition, refrigeration equipment and delivery postcode.

Request a current written offer for the assigned unit. Confirm the dispatch depot, availability, applicable GST, transport, unloading and site work. A missing charge is unresolved, not zero.

Configuration to quoteEquipment evidenceAustralian price confirmation
Used refrigerated containerUnit and machine identity; box condition; dated temperature test; warranty termsCurrent total in AUD including applicable GST
Used box with replacement refrigerationIdentify the box and replacement machine separately; 50 Hz compatibility; guaranteesConfirm equipment, delivery, unloading and site electrical costs
New or one-trip reeferActual condition, machinery specification, temperature duty and electrical nameplateSupplier confirms availability and complete written scope

Working refrigeration

Request the machine identity, a dated operating test at the required temperature and checks of alarms, defrost and door seals.

Box and cooling system

Compare insulation, floor, repairs and equipment age separately. A new motor can be fitted to a used box; request the warranty terms for each.

Delivered total

Have the quote separate equipment, any transformer or conversion, transport, unloading, taxes and site electrical work.

PLAN THE UNIT AND THE TRUCK

Check the long unloading route and machinery access

The installed 40ft rectangle is only part of the site plan. Confirm the delivery truck’s straight approach, turns, tilt clearance and unloading method, then set the doors and machinery-end access before placement.

Truck approachConfirm turns, straight unloading space, ground conditions and overhead clearance with the actual delivery operator.
Door orientationPosition the cargo doors for the receiving route and the way goods will be retrieved.
Machinery accessLeave the refrigeration end accessible for ventilation and maintenance, using the offered unit’s requirements.
Electrical connectionConfirm the supply and connection work before delivery; identify who handles installation and commissioning.
YOUR BUYING QUESTIONS

Refrigerated container FAQs

Does high cube add more floor space?

The paired 40ft examples have the same 11.602 × 2.276 m interior floor. High cube adds 305 mm of published interior height. Check load height, doorway clearance and the actual unit’s load line.

Can one 40ft room hold products at different temperatures?

One high-cube room adds height, without separate temperature zones. Give each product’s required conditions in the request; different temperatures may need separate equipment or a specifically designed arrangement.

Can a 40ft refrigerated container run on single phase?

Confirm the selected equipment is suitable for the Australian site supply: nominal 230 V single phase or 400 V three phase, 50 Hz. Have a licensed electrician check the nameplate, current, connection, protection and any transformer.

What should a delivered 40ft quote include?

Specify standard or high cube, working condition, cooling duty, site supply, delivery postcode and unloading access. Ask for equipment, options, a dated refrigeration test, delivery, unloading, taxes and electrical setup as separate items.