
3m (10ft)
A small on-site inventory or a constrained placement area.
Door configuration can change pallet positions. Small size alone does not establish household-outlet compatibility.
View 3m (10ft) details →Compare offers from multiple suppliers. Find the right price for your project.
Compare refrigerated containers by usable space, temperature range, site power and purchase cost. Explore 3m (10ft), 6m (20ft) and 12m (40ft) formats, then prepare a request for your load and delivery postal code. The geometry illustrations are international reference examples; local equipment and prices require a written supplier offer.


A small on-site inventory or a constrained placement area.
Door configuration can change pallet positions. Small size alone does not establish household-outlet compatibility.
View 3m (10ft) details →
A moderate pallet inventory with regular receiving.
Reserve retrieval and loading access before treating every advertised position as usable storage.
View 6m (20ft) details →
A larger batch held at temperature.
More floor length requires a loading and retrieval plan. Compare standard height with high cube; energy use does not follow a fixed 2× rule.
View 12m (40ft) details →Holding already chilled or frozen goods is a different duty from cooling warm arrivals or freezing a batch. State the incoming temperature, quantity and completion time when that work is required. An insulated shell without working refrigeration provides no active temperature control.
Measure your actual pallets and packed goods before planning positions. CHEP’s South African catalogue includes 1 200 × 1 000 mm pallets and other formats. The diagrams below retain an international 1 219 × 1 016 mm reference footprint; their counts are not capacities for your South African load. Check the selected floor plan, packaged overhang, airflow gaps, load line, doors and retrieval routine.
These drawings show international geometry examples. Confirm the actual South African unit’s dimensions, pallet arrangement, refrigeration equipment, electrical supply and operating requirements with the supplier.
| Portable example | Published inside floor, L × W | Documented pallet positions | Configuration limit |
|---|---|---|---|
| Portable 3m (10ft) example | 2.337 × 2.235 m (7 ft 8 in × 7 ft 4 in) | 3 with a butcher door; 4 with 3/2/1 swing doors | The 3m (10ft) sheet limits front-row pallet height to 1539.2 mm (60.6 in). |
| Portable 6m (20ft) example · three phase | 5.410 × 2.235 m (17 ft 9 in × 7 ft 4 in) | 9 | Inside height 2.540 m (8 ft 4 in); the permitted cargo height still follows the unit loading instructions. |
| Portable 12m (40ft) example | 11.582 × 2.235 m (38 ft × 7 ft 4 in) | 20 | The published count does not identify one height variant; no interior height is assumed here. |
One floor layer of nominal pallet footprints, shown at the same scale. The 3m (10ft) plan illustrates the four-position door option; another door option is rated for three. These drawings reserve no cargo or handling clearance and are not approved food-loading plans. Keep merchandise within the unit airflow and loading limits.
For these international portable examples, the original handling guide uses 51 mm (2 in) between merchandise and sidewalls, 305 mm (12 in) below the ceiling and 152–305 mm (6–12 in) at the rear doors. These are reference-fleet instructions, not universal clearances for South African equipment. Use the selected unit’s loading instructions; packed goods, handling equipment and an aisle can reduce usable positions.
For an explicit planning scenario, assume packaged goods fill each 1 219 × 1 016 mm footprint, reserve 51 mm (2 in) at both sidewalls and choose 305 mm (12 in) at the rear doors. The clearance illustrations demonstrate 2 positions in the portable 3m (10ft) reference, 8 in the 6m (20ft) reference and 18 in the 12m (40ft) reference. These are illustrative placements before any retrieval aisle, front machinery or handling clearance; they are not validated storage capacities.
Illustrative planning scenario, not validated storage capacity: packaged goods fill each pallet footprint, with 50.8 mm (2 in) reserved at the sidewalls and 304.8 mm (12 in) at the rear doors on the right. Height limits, machinery airflow, handling space and retrieval access still need to be checked.
Marine bottom-airflow reefers have separate T-bar floor and load-line rules. Interior height is not the permitted loading height. Pallet positions do not establish payload or stacking limits, or suitability for a particular food.
Prices vary with condition, specification, availability and delivery location. Request a quote for your project. Confirm the refrigeration equipment and working condition. Power setup, transport, unloading, placement and repairs are separate.
| Configuration and inclusions | Estimated price |
|---|---|
| 10ft used refrigerated storage container with working cooling, specialist or cut-down configuration; electrical work extra | from R143,000 · low-end estimate, incl. VAT |
| 20ft used refrigerated container with working refrigeration; power connection and commissioning excluded | from R130,000 · low-end estimate, incl. VAT |
| 40ft used refrigerated container with working refrigeration; power connection and commissioning excluded | from R165,000 · low-end estimate, incl. VAT |
Compare box condition and machinery separately. A used box with a new refrigeration system remains a used box; a nominal length alone does not establish height, equipment age, performance or value.
Local suppliers offer single- and three-phase refrigeration systems. Obtain the actual machine nameplate, voltage, phase, frequency, current and connector. Ask an electrician to confirm the available site supply, protective equipment and any transformer before delivery; a plug adapter does not establish compatibility.
Do not assume that a refrigerated container can use a normal household socket. Big Box publishes single- and three-phase configurations in its South African range; the assigned machine and electrical installation determine the required supply.
| Configuration example | Local supplier range to confirm | Published connection | Normal household outlet? |
|---|---|---|---|
| Local single-phase configuration to request | Local listed systems: −20°C to +20°C; actual unit must confirm | Supplier confirms voltage, frequency, current and connection | Compatibility must be confirmed by your electrician |
| Local 6m (20ft) configuration to request | Local listed systems: −20°C to +20°C; actual unit must confirm | Local three-phase configuration; verify actual machine nameplate | Compatibility must be confirmed by your electrician |
| Local 12m (40ft) standard configuration to request | Local listed systems: −20°C to +20°C; actual unit must confirm | Local three-phase configuration; verify actual machine nameplate | Compatibility must be confirmed by your electrician |
| Local 12m (40ft) High Cube configuration to request | Local listed systems: −20°C to +20°C; actual unit must confirm | Local three-phase configuration; verify actual machine nameplate | Compatibility must be confirmed by your electrician |
A selectable temperature or product-sheet range is not a measured product temperature, a pull-down time or a food-storage recommendation. The four products above do not provide a verified ambient operating limit in this comparison.
Connection ratings are separate from measured operating consumption. Match the actual machine voltage, phase, frequency, connector and circuit with its manufacturer instructions and your electrician. Have the supplier confirm suitability for the available South African site supply before delivery.
Electricity use depends on the refrigeration system, temperature setting, weather, load and door openings. There is no verified size-only ratio here: a matched daily-energy test for the 3m (10ft), 6m (20ft) and 12m (40ft) examples was not available.
| Information to request | What it establishes |
|---|---|
| Measured electrical input and energy use | Request metered kW and accumulated kWh with temperature, ambient conditions, load, door use and test duration stated |
| Cooling capacity at the stated duty | Request manufacturer or specialist capacity and test conditions; heat removal in kW is distinct from electrical input |
For electricity costs, multiply metered kWh for the actual operating conditions by your applicable ZAR/kWh tariff. Identify fixed charges and VAT separately. No assumed electricity tariff or running schedule is used here.
For an operating budget, use accumulated meter kWh over representative holding periods, then multiply by the applicable energy rate. Record warm-load cooling separately. Weather, insulation, doors, defrost, ventilation and humidity control affect the result. Demand charges, fixed fees, taxes, maintenance and generator fuel are outside this energy-only calculation.
These manufacturer examples are different products from the portable fleet above. Dimensions are nominal; the pallet counts above do not transfer to them.
| Marine product example | Approximate dimensions in feet | Inside L × W × H, metres | Door W × H, metres |
|---|---|---|---|
| Marine 6m (20ft) example | 17.46 × 7.33 × 7.38 ft | 5.321 × 2.235 × 2.248 m | 2.235 × 2.248 m |
| Marine 12m (40ft) standard example | 38.06 × 7.47 × 7.30 ft | 11.602 × 2.276 × 2.226 m | 2.276 × 2.299 m |
| Marine 12m (40ft) high cube example | 38.06 × 7.47 × 8.30 ft | 11.602 × 2.276 × 2.531 m | 2.276 × 2.603 m |
The high-cube example adds interior height, while its floor length and width match this standard-height example. Use the proposed unit floor, doorway and load line for a packaged-load plan; dry-container dimensions are not a reefer specification.
A non-operating reefer or NOR shell is not a working refrigerated purchase. For a used working unit, match condition photos, the machinery identity and the dated test report to the offered container. A PTI can include cooling and heating checks; review the procedure, results, skipped checks and repairs. A display photo shows one reading, rather than the temperature history or the performance of your load.
Have the quote itemise the shell and refrigeration, testing or repairs, delivery and placement, electrical equipment and setup, and taxes. Separate shell warranty from refrigeration warranty. Give the delivery operator the postal code, approach and placement photos, offloading access and door orientation; retain access to the machinery for service. Moving an empty reefer is a different arrangement from carrying cold goods under power.
Before taking over the installed container, agree on the operating conditions, records and named contacts below. Confirm which recording and notification functions are included in the delivered configuration.
| Handover item | Evidence to keep | Person to name |
|---|---|---|
| Unit identity and handover file | Container and refrigeration identifiers; document list and unresolved items. | Person handing over the equipment; person accepting the file. |
| Operating conditions and site checks | Agreed duty, load, ambient and door-use assumptions; completed check record and outstanding conditions. | Person completing the checks; person accepting the operating conditions. |
| Sensors and stored history | Recorded sensor or channel and its location; logging settings, retention period, and whether and how records can be exported. | Person checking readings and keeping the records. |
| Remote notification, if supplied | Installed alert capability, connectivity and power-loss behaviour; named recipient and confirmation that the agreed notification reaches them. | Person verifying notification delivery; alert recipient. |
| Response to an alarm or failure | Named response owner, contact route and agreed action; note any service arrangements still unresolved. | Operating contact; person responsible for intervention. |
| Loss of refrigeration or site power | Agreed contingency for the stored goods, including any alternative storage or power arrangement; record unresolved arrangements. | Person authorised to activate the contingency. |
A displayed reading or stored history does not establish that an alert has reached someone who will act on it. A recorder battery does not establish refrigeration backup power.
Choose a format and chilled or frozen holding duty below to keep both in the editable request notes.
Add your load, required temperature, site power and delivery details. Review the format and intended-use selections before sharing the draft. The request builder prepares a draft you can edit, copy or download. Sending through the quote form requires your consent and a separate send action.