🇮🇪 Republic of Ireland · €United States site
REFRIGERATED STORAGE

20ft Refrigerated Containers for Sale

A 20ft refrigerated format for palletised batches or regularly accessed stock. Match the cargo-door or walk-in configuration to your load, power supply and delivery site.

20ft standard height

Nominal format
20ft
Outside height
2.591 m (8 ft 6 in)
Example supply
Three phase

Request a delivered quote

Delivery Eircode is optional at this stage. If your site has no assigned Eircode, add its town, county and delivery address in the full request builder.

The supplier confirms the actual unit, working condition and delivery details.

THE SPACE YOU CAN PLAN AROUND

Exterior, interior and door dimensions

“20ft” is a nominal format name. This documented cargo-door example lists a 6.058 m (19ft 10½in) exterior length; its paired interior and doorway figures are shown below.

Standard-height cargo-door example

Swipe the table to see every column.

MeasurementLengthWidthHeight
Exterior, metric with imperial reference6.058 m (19 ft 10½ in)2.438 m (8 ft)2.591 m (8 ft 6 in)
Exterior, metric6.058 m2.438 m2.591 m
Interior, metric5.321 m2.235 m2.248 m
Cargo-door opening—2.235 m2.248 m

Exterior, interior and cargo-door figures describe this one documented example. Door opening and interior height are separate measurements; confirm the actual unit, floor and load line.

MATCH THE LOAD AND THE MACHINE

Choose the doors, airflow and electrical setup together

Palletised receiving

Cargo doors and a T-floor suit a batch loading routine. Keep goods within the marked cargo-floor boundary and below the load line, following the actual unit’s airflow instructions.

Stock picked throughout the day

Plan how each item can be reached. A single-door walk-in or portable layout can serve a different routine; compare its clearances and refrigeration separately.

Warm arrivals and door openings

Specify holding temperature, incoming product temperature, batch size and door frequency. A selectable range does not establish how quickly a warm load will cool.

Swipe the table to see every column.

Selection itemConfirm for the offered unit
Required temperatureProduct requirement, incoming temperature, holding or pull-down duty, ambient conditions and door-opening routine.
Electrical connectionNameplate voltage, phase, frequency, current and connector; have a qualified electrical contractor check the Irish site supply.
Operating costMetered kWh for a comparable duty, your energy tariff and any demand or fixed charges.

Confirm the offered machine’s installation requirements before delivery. For operating costs, use metered kWh under comparable weather, load and door-opening conditions.

INSIDE THE UNIT. AT YOUR SITE.

Technical checks for a 20ft storage routine

Choose a 20ft cargo-door reefer for a planned palletised batch; compare a walk-in layout when cartons must be reached repeatedly without moving the rest of the load.

Use one configuration’s room and doorway

The cargo-door example has a 5.321 × 2.235 × 2.248 m interior and a 2.235 × 2.248 m door opening. Portable and converted walk-in dimensions describe separate layouts.

  • Put the packaged load and its handling dimensions on the offered unit’s floor plan.
  • Include the actual doorway, floor type and machinery end in the plan.
  • Request a separate dimension sheet if the quote changes to a portable or single-door conversion.

Agree the retrieval pattern before the pallet count

A receiving batch and stock picked throughout the day need different access plans. The marine T-floor distributes air; a geometric aisle or a portable model’s pallet count does not validate its loading pattern.

  • Mark which goods need individual access and the sequence in which pallets will leave.
  • Obtain the loading instructions for the actual floor and marked load line.
  • Give the supplier the incoming product temperature, batch size and expected door-opening routine.

Specify a conversion by its installed equipment

For a converted walk-in unit, identify the installed refrigeration system and obtain its nameplate and connection instructions. Have a qualified electrical contractor assess the site installation.

  • Confirm whether the quote covers a marine unit, portable system or converted walk-in.
  • Request the installed motor identity, nameplate and required connection work.
  • For a converted used box, inspect the shell separately and obtain the refrigeration installation record and warranty terms.

Receive the 20ft box and machine as quoted

A new cooling motor does not make the shell new. Match the delivered access layout and refrigeration equipment to the documents before using the box for the intended load.

  • Match unit and machine identifiers, door arrangement and floor type to the quote.
  • Photograph insulation, seals, floor condition and any repairs identified in the condition report.
  • Obtain a dated test at the required temperature and the machine’s alarm or defrost check results.
  • Keep the confirmed electrical connection, refrigeration service arrangements and separate box/equipment warranty terms.

Compare an Irish delivered quote

Request a current, itemised euro quote for the exact refrigeration unit and insulated box and Irish delivery address. An equipment price alone is not the delivered project total.

Quote itemConfirm in writing
EquipmentSize, condition, identified unit, included fittings and availability at the time of enquiry.
TransportCollection location, delivery Eircode or site address, route, timing, ferry costs where relevant, and any access restrictions.
Unloading and placementHIAB or separate crane arrangements, lifting reach, ground assessment, waiting time and responsibility for the final position.
VAT and additional workConfirm whether each amount includes VAT. Consumer-facing totals should include applicable VAT and unavoidable charges. Identify electrical work, supports and other excluded work separately.
Validity and paymentWritten quote expiry, deposit, balance date, cancellation terms and the party taking payment.

Include the cooling-unit model, a dated operating test, required temperature, power supply, alarms and service history. Obtain an electrician’s assessment of the supply and connection.

Irish stock, supplier coverage and final prices must be confirmed by the seller.

PLAN THE UNIT AND THE TRUCK

Choose the shorter box with its full working space

Check the receiving route, doorway access, machinery clearance and delivery vehicle before choosing the 20ft footprint. Compare a compact or longer format when the load or approach changes.

Truck approachConfirm turns, straight unloading space, ground conditions and overhead clearance with the actual delivery operator.
Door orientationPosition the cargo doors for the receiving route and the way goods will be retrieved.
Machinery accessLeave the refrigeration end accessible for ventilation and maintenance, using the offered unit’s requirements.
Electrical connectionConfirm the supply and connection work before delivery; identify who handles installation and commissioning.
YOUR BUYING QUESTIONS

Refrigerated container FAQs

Can a 20ft reefer plug into an ordinary outlet?

Confirm the actual unit’s nameplate, voltage, phase, frequency, connector and capacity against the Irish site supply. Ask a qualified electrical contractor to assess the installation; an ordinary socket does not establish compatibility.

Does a new cooling motor make the box new?

A used box with a new motor remains a used box. Inspect the insulation, seals, floor and repairs alongside the cooling system, and obtain the warranty terms for each.

How many pallets can a 20ft refrigerated container hold?

Request a model-specific loading plan for the actual pallet footprints and packaged dimensions. Euro pallets commonly measure 1,200 × 800 mm. Include overhang, loading access, air circulation and floor-load limits before agreeing capacity.

What confirms that a used reefer provides active cooling?

Request the offered machine’s identity, a dated refrigeration test, operation at the required temperature and checks of alarms and defrost. An insulated box with non-working refrigeration is a different purchase.

YOUR LOAD. YOUR POWER. YOUR DELIVERY Eircode.

Prepare a request for the configuration you need.

Compare the cooling needs and delivery work together.

Prepare my quote request ↗

Plan this purchase for an Irish site

Specify the required temperature in °C, Euro-pallet or packaged load, operating routine, and site voltage, phase and frequency. Ask for the exact cooling-unit model, service record and a dated operating test.

Use a delivery Eircode where available, plus the town, county, access photographs and proposed position. New or unassigned sites can be described by a full address and location instructions. Ask the operator to assess lane width, bends, overhead lines, ground support and HIAB or crane placement.

Compare itemised euro offers with applicable VAT, delivery, unloading and required site work visible. Supplier coverage, stock and appointment dates need confirmation for the actual location.