Choose refrigerated storage for your New Zealand site by usable room, packaged load, holding temperature and the actual refrigeration machine. Compare metric model examples, confirm 50 Hz site compatibility and request a tested unit with its full NZD scope and GST stated.
20ft GP ISO
Outside L × W
6.06 × 2.44 m
Outside height
2.6 m
Site power
Exact machine + 50 Hz compatibility
Request a delivered quote
The supplier confirms the actual unit, working condition and delivery details.
20ft HC single phase
Outside L × W
6.06 × 2.44 m
Outside height
2.9 m
Site power
Exact machine + 50 Hz compatibility
Request a delivered quote
The supplier confirms the actual unit, working condition and delivery details.
20ft HC pallet wide
Outside L × W
6.06 × 2.5 m
Outside height
2.9 m
Site power
Exact machine + 50 Hz compatibility
Request a delivered quote
The supplier confirms the actual unit, working condition and delivery details.
THE SPACE YOU CAN PLAN AROUND
Exterior, interior and door dimensions
Compare the metric NZ-market examples below. Insulation, machine location, floor and door configuration reduce usable space; the exact offered unit must be confirmed.
Documented NZ-market configuration example
Swipe the table to see every column.
Measurement
Length
Width
Height
Exterior (m)
6.06 m
2.44 m
2.6 m
Interior (m)
5.45 m
2.29 m
2.28 m
Door opening (m)
—
2.29 m
2.26 m
Dimensions belong to this NZ configuration example. Confirm the allocated box, clear door, floor and marked load line; do not mix measurements from other variants.
Documented NZ-market configuration example
Swipe the table to see every column.
Measurement
Length
Width
Height
Exterior (m)
6.06 m
2.44 m
2.9 m
Interior (m)
5.19 m
2.29 m
2.59 m
Door opening (m)
—
1.79 m
2.46 m
Dimensions belong to this NZ configuration example. Confirm the allocated box, clear door, floor and marked load line; do not mix measurements from other variants.
Documented NZ-market configuration example
Swipe the table to see every column.
Measurement
Length
Width
Height
Exterior (m)
6.06 m
2.5 m
2.9 m
Interior (m)
5.45 m
2.39 m
2.57 m
Door opening (m)
—
2.39 m
2.53 m
Dimensions belong to this NZ configuration example. Confirm the allocated box, clear door, floor and marked load line; do not mix measurements from other variants.
MATCH THE LOAD AND THE MACHINE
Choose the doors, airflow and electrical setup together
Packaged load and retrieval
Use the actual packaged load. The NZ blue-pallet reference is 1,200 × 1,000 mm; an Australian pallet is a different 1,165 × 1,165 mm footprint. Allow for wrapping, airflow and retrieval; container length alone cannot establish a safe pallet count.
Temperature and incoming goods
Specify the held temperature in °C, arrival temperature, batch mass and any cooling or freezing deadline. Holding a cold batch and cooling warm arrivals require separate duty selection.
Actual NZ site connection
New Zealand sites use 50 Hz electricity, with nominal 230 V single-phase and 400 V three-phase supplies. Have an electrician match the actual machine’s voltage range, phase, 50 Hz compatibility, current, connector and circuit to the site before delivery.
Swipe the table to see every column.
Separate local supplier range
Published holding range
Published connection example
Single-phase chiller
0°C to +20°C
15 A / 240 V; exact frequency and connector to confirm
Three-phase refrigerated range
−25°C to +20°C
32 A / 415 V; exact frequency and connector to confirm
These supplier-range figures are not a universal rating for every illustrated variant. Require the actual machine’s compatible voltage range and 50 Hz operation; the NZ nominal supply is 230/400 V. A transformer or conversion needs its own input and commissioning specification.
INSIDE THE UNIT. AT YOUR SITE.
Technical checks for the offered NZ configuration
Keep the box, actual refrigeration machine and site connection together through selection and handover.
Measure the offered room and doorway
Use its actual interior, clear door, floor and marked load line; the visual is a concept and the table is a model example.
Packaged length, width and height in mm, including pallet and wrapping
Actual clear opening and handling space
Manufacturer airflow and loading instructions
Match the cold-storage duty
The setpoint does not establish pull-down performance. Ask for evidence for your load and operating conditions.
Arrival and holding temperatures in °C
Batch mass, daily load and door routine
Dated operating test and alarm/defrost checks
Confirm the site circuit before delivery
New Zealand sites use 50 Hz electricity, with nominal 230 V single-phase and 400 V three-phase supplies. Have an electrician match the actual machine’s voltage range, phase, 50 Hz compatibility, current, connector and circuit to the site before delivery.
Machine nameplate photograph
Supplier connection and commissioning requirements
Electrician review of current, connector and 50 Hz compatibility
Receive the assigned unit and records
Match delivered identifiers, condition photographs and test report to the quote.
Door, seals, floor and insulation condition
Dated run test, controls and emergency release where fitted
Separate shell/equipment warranty and service scope
Agreed unloading orientation and machinery access
Compare the complete refrigerated-container quote
Confirm the actual unit, refrigeration equipment, operating test and warranty. Ask for the full NZD total with GST, transport, unloading, electrical work and commissioning clearly identified. A non-operational insulated shell does not provide active cooling.
PLAN THE UNIT AND THE TRUCK
Choose the shorter box with its full working space
Give the operator the full address, suburb/town, region and postcode, with access photographs. Confirm HIAB or swinglift delivery, the actual unloading side, door direction, overhead services, firm ground and the complete placement scope. Leave the refrigeration machine accessible for ventilation and service.
Truck approachConfirm turns, straight unloading space, ground conditions and overhead clearance with the actual delivery operator.
Door orientationPosition the cargo doors for the receiving route and the way goods will be retrieved.
Machinery accessLeave the refrigeration end accessible for ventilation and maintenance, using the offered unit’s requirements.
Electrical connectionConfirm the supply and connection work before delivery; identify who handles installation and commissioning.
YOUR BUYING QUESTIONS
Refrigerated container FAQs
Can this reefer run from a normal household outlet?
Confirm the actual machine. The documented single-phase chiller range requires 15 A / 240 V; three-phase units have separate requirements. A household outlet, plug adapter or smaller box does not establish compatibility. Have an electrician check the nameplate, 50 Hz supply, current and connector.
How many pallets will fit?
Use the actual packaged load. The NZ blue-pallet reference is 1,200 × 1,000 mm; an Australian pallet is a different 1,165 × 1,165 mm footprint. Allow for wrapping, airflow and retrieval; container length alone cannot establish a safe pallet count. Obtain the proposed model’s loading instructions and a floor plan with clearance and retrieval space.
Does an insulated container provide refrigeration?
A non-operational reefer or insulated shell has no active cooling. Request operating refrigeration, a dated run test at your required temperature and written equipment warranty terms if temperature control is required.
What belongs in the full delivered price?
The allocated box and refrigeration machine, repairs/testing, accessories, delivery, unloading, electrical setup, commissioning and GST. Compare the same duty and site in each proposal.